in-row air condktionerL series is a serles of precision airconditioners for high heat density data centers. It has variaus refrigeratlion methods such as air-cooled direct expansion type and chilled water type. Designed close to the heat source, cosing thecold and hot aisles, greatly improving the cooling effidency, and eftectively reducing the PLE af the equipment room through high AER system design and precise control
| No. | Description | Model | |||||
| 1 | Model | L25 | |||||
| 2 | Unit performance | Air volume (m³/h) | 5500 | ||||
| 3 | Cooling capacity (kW) | 25.2 | |||||
| 4 | Number of compressors (units) | 1 | |||||
| 5 | Operating mode | Constant temperature and humidity type | |||||
| 6 | Compressor type | Variable frequency scroll compressor | |||||
| 7 | External static pressure (Pa) | 50--300 | |||||
| 8 | Power supply (V) | 220V-3Ph-60Hz | |||||
| 9 | refrigerant | R410A | |||||
| 10 | Expansion valve | Electronic expansion valve | |||||
| 11 | Electric heating type | PTC | |||||
| 12 | Electric heating power (kW) | 3 | |||||
| 13 | Humidifier type | wet film | |||||
| 14 | Humidification rate (kg/h) | 3 | |||||
| 15 | Temperature control range (°C) | 18-30 | |||||
| 16 | Humidity control range (RH%) | 45-70 | |||||
| 17 | Temperature control accuracy (°C) | ±2 | |||||
| 18 | Humidity control accuracy (RH%) | ±5 | |||||
| 19 | Indoor unit | Evaporator type | Copper tube with aluminum fins | ||||
| 20 | air filter | G4 Level Initial Effect | |||||
| 21 | Indoor fan type | EC | |||||
| 22 | External dimensions (mm) | W | 300 | ||||
| 23 | D | 1200 | |||||
| 24 | H | 2000 | |||||
| 25 | Unit weight (Kg) | 295 | |||||
| 26 | outdoor unit | Condenser type | Copper tube sleeve aluminum fin | ||||
| 27 | Number of outdoor units (units) | 1 | |||||
| 28 | Outdoor unit weight (Kg) | 125 | |||||
| 29 | External dimensions (mm) | W | 850 | ||||
| 30 | D | 550 | |||||
| 31 | H | 1600 | |||||
| 32 | other | Indoor unit air supply method | Rear intake/front discharge | ||||
| 33 | Tracheal tube dimensions (φmm) | 19 | |||||
| 34 | Liquid tube dimensions (φmm) | 16 | |||||
| 35 | Condensate drain pipe (φmm) | 19 | |||||
| 36 | Humidifier water inlet pipe (φmm) | G1/2" | |||||
| 37 | It is recommended to use the main cable. | 10²*3+4²*2 | |||||
| 38 | Cables are used to connect indoor and outdoor units. | 2.5²*3 | |||||
| 39 | Remote control system interface | RS485 | |||||
| 40 | It has a power failure memory function | Automatic power-on after power failure and reset | |||||
![]()
![]()
![]()